637
yesterday 465
visitor 1,516,557

Turn-On Fluorescence Sensing of Oxygen with Dendrimer-Encapsulated Platinum Nanoparticles as Tunable Oxidase Mimics for Spatially Resolved Measurement of Oxygen Gradient in a Human Gut-on-a-Chip

?

단축키

Prev이전 문서

Next다음 문서

+ - Up Down Comment Print
?

단축키

Prev이전 문서

Next다음 문서

+ - Up Down Comment Print
Extra Form
Journal Turn-On Fluorescence Sensing of Oxygen with Dendrimer-Encapsulated Platinum Nanoparticles as Tunable Oxidase Mimics for Spatially Resolved Measurement of Oxygen Gradient in a Human Gut-on-a-Chip
Author Hyein Lee, Woojung Shin, Hyun Jung Kim, Joohoon Kim
Citation Anal. Chem. 2021, 93, 48, 16123?16132
DOI https://doi.org/10.1021/acs.analchem.1c03891
Turn-on type fluorescence sensing of O2is considered a promising approach to developing ways to measure O2in microenvironments with spatially distributed O2levels. As a class of nanomaterials with a high degree of control over composition and structure, dendrimer-encapsulated nanoparticles (DENs) are promising candidates to mimic biological enzymes. Here, we report a strategy to monitor spatially distributed O2across a three-dimensional (3D) human intestinal epithelial layer in a gut-on-a-chip in a turn-on fluorescence sensing manner. The strategy is based on the oxidase-mimetic activity of Pt DENs for catalytic oxidation of nonfluorescent Amplex Red to highly fluorescent resorufin in the presence of O2. We synthesized Pt DENs using two different types of dendrimers (i.e., amine-terminated or hydroxyl-terminated generation 6 polyamidoamine (PAMAM) dendrimers) with six different Pt2+/dendrimer ratios (i.e., 55, 200, 220, 550, 880, and 1320). After clarifying the intrinsic oxidase-mimetic activity of Pt DENs, we determined tunable oxidase-mimetic activity of Pt DENs, especially with fine-tuning the ratios of the Pt precursor ions and dendrimers. Particularly, the optimal Pt DENs having a Pt2+/dendrimer ratio of 1320 exhibited an ∼117-fold increase in the oxidase-mimetic activity for catalyzing the aerobic oxidation of Amplex Red to resorufin compared to one having a Pt2+/dendrimer ratio of 200. This study exemplified a simple yet effective approach for spatially resolved imaging of O2using metal nanoparticle-based oxidase mimics in microphysiological environments like a human gut-on-a-chip.

  1. Graphene oxide hybrid with amine-terminated poly(amidoamine) dendrimers encapsulating Pt nanoparticles for electrochemical oxygen reduction reaction

    Category2022 AuthorJiwoong Kim,Joohoon Kim Journalbulletin of the korean chemical society CitationBull. Korean Chem. Soc. 2022;43:69-72 file
    Read More
  2. Strategy for Efficient H2 Production from a Mixture of Formic Acid and Formate using Operando pH Measurements

    Category2022 AuthorChan Kim, Kimoon Lee, Il Han Yoo, Yu Jin Lee, Safira Ramadhani, Hyuntae Sohn, Suk Woo Nam, Joohoon Kim, Yongmin Kim, Hyangsoo Jeong JournalACS Sustainable Chem. Eng. CitationACS Sustainable Chem. Eng. 2022, 10, 2, 888-898 file
    Read More
  3. Ratiometric fluorescence probe based on monochromatic dual-emission carbon nanodots with fluorescence spectral change

    Category2022 AuthorAniruddha Molla, Hyein Lee, Youngwon Ju, Jeongyun Choi, Joohoon Kim JournalDyes and Pigments CitationDyes and Pigments, 2022, Volume 197, 0143-7208 file
    Read More
  4. Indium tin oxide bipolar electrodes modified with Pt nanoparticles encapsulated inside dendrimers as sensitive electrochemiluminescence platforms

    Category2022 AuthorJihun Woo, Jiwoong Kim, Joohoon Kim JournalJournal of Electroanalytical Chemistry CitationJournal of Electroanalytical Chemistry, 2022, Volume 906, 1572-6657 file
    Read More
  5. Turn-On Fluorescence Sensing of Oxygen with Dendrimer-Encapsulated Platinum Nanoparticles as Tunable Oxidase Mimics for Spatially Resolved Measurement of Oxygen Gradient in a Human Gut-on-a-Chip

    Category2021 AuthorHyein Lee, Woojung Shin, Hyun Jung Kim, Joohoon Kim JournalTurn-On Fluorescence Sensing of Oxygen with Dendrimer-Encapsulated Platinum Nanoparticles as Tunable Oxidase Mimics for Spatially Resolved Measurement of Oxygen Gradient in a Human Gut-on-a-Chip CitationAnal. Chem. 2021, 93, 48, 16123?16132 file
    Read More
Board Pagination ‹ Prev 1 ... 7 8 9 10 11 12 13 14 15 16 Next ›
/ 16

나눔글꼴 설치 안내


이 PC에는 나눔글꼴이 설치되어 있지 않습니다.

이 사이트를 나눔글꼴로 보기 위해서는
나눔글꼴을 설치해야 합니다.

설치 취소

Designed by sketchbooks.co.kr / sketchbook5 board skin

Sketchbook5, 스케치북5

Sketchbook5, 스케치북5

Sketchbook5, 스케치북5

Sketchbook5, 스케치북5

 
  • 02447 서울특별시 동대문구 경희대로 26(회기동, 경희대학교) 스페이스21 이과대학 803호
    Rm. 102, Humanity bldg., Kyung Hee University, 26 Kyungheedae-ro, Dongdaemun-gu, Seoul, 130-701, Korea
    TEL) Office : +82 2 961 9384 / Lab : + 82 2 961 2294 / Fax : + 82 2 966 3701  |