Journal | Biosensors and Bioelectronics |
---|---|
Author | Jihye Kwon, Seo Kyoung Park, Yongwoon Lee, Je Seung Lee and Joohoon Kim |
Citation | Biosensors and Bioelectronics 87 2017 89?95 |
DOI | http://dx.doi.org/10.1016/j.bios.2016.08.013 |
We report a method to tailor chemically converted graphenes (CCGs) using a water-soluble pyrene derivative (1) with a zwitterionic arm, and the feasibility of the tailored CCGs to sensitive electrochemiluminescence (ECL)-based analyses. The compound 1 serves the dual purpose of improving the dispersion of the CCGs in aqueous solutions and further tailoring the catalytic activity of the CCGs with dendrimer-encapsulated catalytic nanoparticles. As a model system, we conjugated dendrimer-encapsulated Pt nanoparticles to the 1-functionalized CCGs on indium tin oxide (ITO) electrodes. The resulting ITOs exhibited significantly increased ECL emission of the luminol/H2O2 ECL system; i.e. two orders-of-magnitude enhancement in the ECL compared to that obtained from bare ITOs, which allowed a ca. 154 times more sensitive ECL-based analysis of cholesterol using the modified ITOs compared with the use of bare ITOs.